Low Noise Level Compressor
55KW Electrical Motor Screw Compressor
Direct Drive Rotary Screw Air Compressor
Air compressor oil compensating
In the running state, the compressor oil level should be kept
between the lowest and highest oil level, oil will affect the
separation effect, less oil will affect the machine lubrication and
cooling performance in the oil change cycle, if the oil below the
minimum Oil level, should be promptly added lubricants, the method
is:
①.shutdown and other internal pressure release is complete (to
confirm the system without pressure), pull down the power switch.
②.open the oil and gas separation tank on the fuel port, add the
right amount of cooling oil.
③.the normal operation of the air compressor oil change time see
regular maintenance table.
Installation Site Selection
1. Air compressor installation, to be a good place for wide
lighting in order to facilitate the operation and maintenance.
2. The relative humidity of the air should be low, less dust, clean
air and well ventilated, away from flammable and explosive,
corrosive chemicals and harmful unsafe items, to avoid near the
place of dust.
3. Air compressor installation, the installation site of the
ambient temperature should be higher than 5 degrees in winter,
summer should be less than 40 degrees, because the higher the
ambient temperature, the higher the air compressor discharge
temperature, which will affect the performance of the compressor,
necessary , The installation site should be set ventilation or
cooling device.
4. If the factory environment is poor, more dust, to be installed
before the filtration equipment.
5. Air compressor installation site should be arranged in a row of
air compressor unit.
6. Reserved access, with conditions can be installed crane, in
order to facilitate maintenance of air compressor equipment.
7. Reserved maintenance space, air compressor and wall at least 70
cm above the distance.
8. Air compressor from the top space at least one meter above the
distance.
In the case of constant power, when the speed changes, the volumetric flow and the working pressure also changes accordingly; For example: a 22KW air compressor, in manufacturing to determine the working pressure of 7bar, according to the compressor host technology curve Speed, displacement 3.8 m3 / min; when the working pressure is determined to 8bar, the speed must be reduced (otherwise the drive motor overload), then the displacement of 3.6 m3 / min; because the speed decreased, Gas is correspondingly reduced, and so on.
Power selection is to meet the working pressure and volume flow
conditions, the supply capacity to meet the matching drive motor
power can be used.
Therefore, the optional air compressor steps are: first determine
the working pressure, and then set the corresponding volume flow,
and finally the power supply capacity.